Notes: For PCB fabrication, we require PCB design file in Gerber RS-274X format (most preferred), *.PCB/DDB (Protel, inform your program version) format or *.BRD (Eagle) format. For PCB assembly, we require PCB design file in above mentioned format, drilling file and BOM. Click to download BOM template To avoid file missing, please include all files into one folder and compress it into .zip or .rar format.
IPC-4761 Explained: Via Tenting, Plugging, Filling & Capping Guide
Anyone who has dealt with solder wicking through vias during BGA assembly knows the frustration. You place a fine-pitch component, run it through reflow, and find solder has disappeared down the via barrel leaving a starved joint. Or worse, you discover solder balls on the bottom side of your board causing shorts. These problems drove the industry to develop standardized via protection methods, and IPC-4761 is the definitive guide that documents them all.
IPC-4761, titled “Design Guide for Protection of Printed Board Via Structures,” provides PCB designers, fabricators, and assemblers with comprehensive information on protecting vias through tenting, plugging, filling, and capping. Whether you’re routing under a 0.4mm pitch BGA or building HDI boards with stacked microvias, understanding these seven via protection types will save you from costly assembly defects and field failures.
What Is IPC-4761?
IPC-4761 is the sole industry guideline covering all existing methods for protecting vias on printed circuit boards. Released in July 2006, this 16-page standard was developed by the IPC Via Protection Task Group (D-33d) under the Rigid Printed Board Committee.
IPC-4761 Standard Overview
Attribute
Details
Full title
Design Guide for Protection of Printed Board Via Structures
Document number
IPC-4761
Release date
July 2006
Pages
16 pages
Developed by
IPC Via Protection Task Group (D-33d)
Scope
Via tenting, plugging, filling, and capping methods
Via types defined
7 types (Type I through Type VII)
The standard addresses fabrication issues, assembly process concerns, and long-term reliability implications of each via protection method. It also provides material specifications and selection guidance to help engineers choose the right approach for their application.
Why Via Protection Matters in PCB Design
Unprotected vias create multiple problems throughout the PCB lifecycle. Understanding these issues explains why IPC-4761 has become essential reading for anyone involved in board design and manufacturing.
PCB Fabrication Issues
Problem
Description
Impact
Plating solution entrapment
Chemistry trapped in via barrels
Contamination, corrosion
Outgassing
Trapped volatiles escape during thermal cycling
Delamination, blistering
Surface finish contamination
HASL or other finishes wick into vias
Uneven finish, solderability issues
Assembly Process Issues
Problem
Description
Impact
Solder wicking
Solder paste flows down via barrel during reflow
Starved joints, insufficient fillet
Solder balling
Solder escapes through via to opposite side
Short circuits, contamination
Vacuum loss
Open vias prevent proper vacuum hold during placement
Component misalignment
Flux entrapment
Flux residue trapped in vias
Corrosion, electrochemical migration
Long-Term Reliability Concerns
Problem
Description
Impact
Moisture absorption
Open vias absorb humidity
CAF, electrochemical migration
Thermal stress
Different CTE between fill material and copper
Cracking, barrel fatigue
Contamination ingress
Field contaminants enter via structure
Corrosion, intermittent failures
IPC-4761 Via Protection Types Overview
IPC-4761 defines seven distinct via protection types, organized by increasing levels of protection and complexity. Each type has specific applications, advantages, and limitations.
Complete IPC-4761 Via Type Summary
Type
Name
Method
Fill Level
Solderable Surface
I
Tented
Dry film solder mask
None
No
II
Tented & Covered
Dry film + liquid mask
None
No
III
Plugged
Non-conductive paste
Partial
No
IV
Plugged & Covered
Paste + liquid mask
Partial
No
V
Filled
Non-conductive material
Complete
No
VI
Filled & Covered
Fill + liquid mask
Complete
No
VII
Filled & Capped
Fill + copper cap
Complete
Yes
Each type can be applied to one side (designated “a”) or both sides (designated “b”) of the via structure. For example, Type III-a indicates single-sided plugging while Type III-b indicates double-sided plugging.
Type I and Type II: Tented Vias
Tented vias represent the simplest and most economical via protection method. The via barrel remains hollow, but the openings are covered by solder mask material.
Type I: Tented Via
In Type I protection, dry film solder mask is stretched over the via opening during the imaging process. No additional materials are added to the via hole itself.
Specification
Type I-a (One Side)
Type I-b (Both Sides)
Material
Dry film solder mask
Dry film solder mask
Via hole
Remains hollow
Remains hollow
Process
Standard solder mask
Standard solder mask
Reliability
Low – prone to cracking
Moderate
Applications: General protection where via exposure is acceptable after thermal stress. Type I is rarely specified for production boards due to reliability concerns.
Limitations: Dry film tenting can crack under thermal or mechanical stress, exposing the via. This method is considered obsolete for most applications and is primarily found in older military specifications.
Type II: Tented and Covered Via
Type II adds a layer of liquid photoimageable (LPI) solder mask over the dry film tenting, providing additional protection.
Specification
Type II-a (One Side)
Type II-b (Both Sides)
Material
Dry film + LPI mask
Dry film + LPI mask
Via hole
Remains hollow
Remains hollow
Process
Two-step mask application
Two-step mask application
Reliability
Moderate
Good
Applications: Protection of solder from floating through to component side. Used for vias beneath BGA packages where complete sealing isn’t required.
Limitations: The via remains hollow, so thermal cycling can still cause issues. Type II is becoming less common as manufacturers move toward filled via solutions.
Type III and Type IV: Plugged Vias
Plugged vias use non-conductive paste material that partially fills the via barrel. This provides better protection than tenting while remaining more economical than complete filling.
Type III: Plugged Via
Type III protection involves partially filling the via with non-conductive paste, typically using a screen printing process.
Specification
Type III-a (One Side)
Type III-b (Both Sides)
Material
Non-conductive paste
Non-conductive paste
Fill level
Partial penetration
Partial from both sides
Process
Screen printing
Screen printing
Typical fill
50-70% of barrel
70-90% of barrel
Applications: General via protection for standard multilayer boards, prevention of solder wicking in non-critical areas.
Limitations: Achieving consistent fill depth is challenging, especially for smaller via diameters. Vias below 0.3mm are difficult to plug reliably.
Type IV: Plugged and Covered Via
Type IV adds liquid solder mask over the plugged via, providing additional protection and a smoother surface.
Specification
Type IV-a (One Side)
Type IV-b (Both Sides)
Material
Paste + LPI mask
Paste + LPI mask
Fill level
Partial + covered
Partial + covered
Process
Plug then mask
Plug then mask
Surface
Mask covered
Mask covered
Applications: BGA areas where via-in-pad isn’t required but solder wicking prevention is critical. Common for 0.8mm and 1.0mm pitch BGAs.
Limitations: The covered surface isn’t solderable. If components need to be placed directly over vias, Type VII must be used instead.
Via Plugging Process Challenges
Achieving consistent Type III or IV plugging requires careful process control:
Via Size
Screen Strokes
Fill Difficulty
Typical Result
≥0.4mm
5-10
Easy
Full plug achievable
0.3mm
10-15
Moderate
Usually adequate
0.2mm
15-20+
Difficult
Often incomplete
≤0.15mm
20+
Very difficult
May require filled via
For via diameters below 0.3mm in standard board thickness (1.6mm), Type V or higher is often more practical than attempting to plug small holes.
Type V and Type VI: Filled Vias
Filled vias provide complete encapsulation of the via barrel with non-conductive material. This eliminates most problems associated with hollow or partially filled vias.
Type V: Filled Via
Type V vias are completely filled with non-conductive material, targeting full penetration and encapsulation of the hole.
Specification
Details
Material
Non-conductive epoxy or resin
Fill level
100% of via barrel
Process
Vacuum or pressure fill
Surface
May have dimple or bump
Solderable
No
Applications: Sequential lamination processes, buried via structures, HDI boards where complete fill is needed but solderability isn’t required.
Key Benefit: Type V does not require wrap plating, which reduces base copper thickness and allows finer trace spacing. This makes Type V particularly valuable for buried vias in HDI designs.
Type VI: Filled and Covered Via
Type VI adds liquid solder mask over the filled via, providing a protected non-solderable surface.
Specification
Type VI-a (One Side)
Type VI-b (Both Sides)
Material
Fill + LPI mask
Fill + LPI mask
Fill level
100% + covered
100% + covered
Surface
Mask covered
Mask covered
Solderable
No
No
Applications: Situations requiring complete via fill with additional environmental protection but no solderability requirement.
Type V vs Type VII for Buried Vias
For buried via structures, Type V often provides advantages over Type VII:
Factor
Type V
Type VII
Base copper
Thinner (finer spacing)
Thicker (requires wrap plating)
Process steps
20-25 fewer steps
More complex
Cycle time
1-3 days faster
Longer
Compliance risk
Lower
Higher (dimple, cap thickness specs)
Cost
Lower
Higher
Since buried vias aren’t on the surface, the solderable cap of Type VII provides no benefit. Specifying Type V for buried structures improves yields and reduces cost without sacrificing functionality.
Type VII: Filled and Capped Via
Type VII represents the most advanced via protection method and is essential for via-in-pad (VIP) applications. The via is completely filled, planarized, and capped with copper to create a flat, solderable surface.
Type VII Process Overview
Step
Process
Purpose
1
Drill and plate through
Create plated via
2
Clean via barrel
Remove debris, prepare for fill
3
Fill with resin
Non-conductive or conductive material
4
Cure fill material
Harden the fill
5
Planarize surface
Remove excess, create flat surface
6
Metallize/plate cap
Apply copper over filled via
7
Surface finish
Final finish for solderability
Type VII Specifications per IPC-6012
Parameter
Class 2
Class 3
Maximum dimple
0.005″ (125µm)
0.003″ (75µm)
Minimum cap plating
Per IPC-6012 Table 3-11
Per IPC-6012 Table 3-11
Wrap plating
Required
Required
Surface
Flat, solderable
Flat, solderable
Type VII Applications
Application
Why Type VII Required
Via-in-pad (VIP)
Solderable surface under component pad
Fine-pitch BGA (≤0.65mm)
No room for dog-bone fanout
Stacked microvias
Flat surface for subsequent layers
High-speed design
Shortest path, lowest inductance
Thermal management
Heat transfer through filled via
Via-in-Pad Design Guidelines
BGA Pitch
Via-in-Pad Needed
Typical Via Diameter
≥1.0mm
Optional
0.3-0.4mm
0.8mm
Recommended
0.25-0.3mm
0.65mm
Usually required
0.2-0.25mm
0.5mm
Required
0.15-0.2mm
0.4mm
Required
0.1-0.15mm
For pitches below 0.65mm, there typically isn’t enough space between pads for a traditional dog-bone fanout, making via-in-pad with Type VII protection essential.
Via Protection Material Selection
IPC-4761 provides guidance on materials for both fill and tenting applications.
Fill Materials for Plugged and Filled Vias
Material Type
Composition
Applications
Non-conductive (organic)
Epoxy resin
Standard via fill, most common
Non-conductive (photoimageable)
Modified epoxy
Where mask compatibility needed
Conductive
Silver or copper-filled epoxy
Thermal or electrical conductivity
Soldermask
LPI solder mask
Simple plugging (less reliable)
Material Selection Criteria
Criterion
Consideration
CTE match
Should match copper/laminate to prevent stress
Tg (glass transition)
Must exceed assembly temperatures
Moisture absorption
Lower is better for reliability
Adhesion
Must bond to copper barrel
Cure shrinkage
Excessive shrinkage causes dimples
IPC-4761 Via Type Selection Guide
Choosing the right via protection type depends on your application requirements:
Selection by Application
Application
Recommended Type
Rationale
General multilayer, no BGA
Type I or III
Basic protection, low cost
BGA (≥0.8mm pitch)
Type IV
Solder wicking prevention
BGA (<0.8mm pitch)
Type VII
Via-in-pad required
Buried vias (HDI)
Type V
No solderable surface needed
Stacked microvias
Type VII
Flat surface for stacking
High-reliability
Type VI or VII
Complete encapsulation
Selection by Cost and Complexity
Type
Relative Cost
Process Complexity
Lead Time Impact
I
1x (baseline)
Low
None
II
1.1x
Low
Minimal
III
1.3x
Moderate
+1 day
IV
1.4x
Moderate
+1 day
V
1.8x
High
+1-2 days
VI
2.0x
High
+1-2 days
VII
2.5-3x
Very high
+2-3 days
Performance Tradeoffs and Design Considerations
IPC-4761 addresses several performance factors that designers must consider when specifying via protection.
Planarity Requirements
Condition
Cause
Impact
Mitigation
Dimple
Fill shrinkage during cure
Solder voiding on VIP
Specify maximum dimple per IPC-6012
Bump
Excess fill material
Component tilt, tombstoning
Proper planarization process
Void Considerations
Void Location
Concern
Acceptable Level
Center of fill
Minimal impact
Generally acceptable
Near surface
May open during planarization
Reject or rework
Large voids (>50% area)
Structural weakness
Reject
Moisture Absorption
Filled vias with organic materials can absorb moisture, potentially causing:
Delamination during reflow (popcorning)
Electrochemical migration
Reduced insulation resistance
Proper baking before assembly and low-moisture fill materials help mitigate these risks.
Frequently Asked Questions About IPC-4761
What is the difference between via plugging and via filling?
Via plugging (Type III/IV) partially fills the via barrel, typically achieving 50-90% fill depending on via size and process. Via filling (Type V/VI/VII) completely encapsulates the via with material targeting 100% fill. Plugging is simpler and less expensive but provides less protection against solder wicking and contamination. Filling is required for via-in-pad applications and high-reliability designs where complete sealing is necessary. The choice depends on your assembly requirements and reliability needs.
When should I specify Type VII filled and capped vias?
Type VII is required whenever you need a solderable surface directly over a via. The most common application is via-in-pad for fine-pitch BGAs (typically ≤0.65mm pitch) where there isn’t room for traditional dog-bone fanout. Type VII is also necessary for stacked microvia structures in HDI boards, where subsequent vias land on previously filled vias. If your design doesn’t require soldering directly to the via location, Type V or VI provides similar protection at lower cost.
Can I use solder mask to plug vias instead of dedicated fill material?
While some fabricators offer solder mask plugging as a low-cost option, it’s generally not recommended for reliability-critical applications. Solder mask is designed as a surface coating, not a via fill material. It doesn’t achieve consistent fill depth, may crack under thermal stress, and can outgas during reflow. IPC-4761 specifies non-conductive paste or epoxy materials for plugging and filling because these materials are formulated for complete via encapsulation with appropriate thermal and mechanical properties.
How do I call out IPC-4761 via protection on my fabrication drawing?
Specify via protection using the IPC-4761 type designation along with which vias require protection. For example: “All vias within BGA U1 footprint shall be Type VII per IPC-4761” or “Via plug Type IV-b required for vias within 0.5mm of any SMD pad.” Include specific requirements like maximum dimple depth if critical. Reference IPC-6012 for acceptance criteria on filled via planarity and cap plating thickness. Clear callouts prevent misinterpretation and ensure you receive boards that meet your assembly requirements.
What is the cost impact of specifying Type VII via-in-pad?
Type VII filled and capped vias typically add 2.5-3x the cost of unfilled vias and extend lead time by 2-3 days. The process requires additional steps: filling, curing, planarization, and additional plating. However, for fine-pitch BGAs, the cost of Type VII is often offset by reduced assembly defects and higher first-pass yield. Before specifying Type VII for all vias, evaluate which vias actually require it. Many designs can use Type VII only for via-in-pad locations while using less expensive protection elsewhere.
Altium Designer: IPC-4761 via type support in design rules
Cadence Allegro: Via structure definition for manufacturing
KiCad: Via properties and fabrication notes
Conclusion
IPC-4761 provides the essential framework for specifying via protection in modern PCB designs. From simple tenting to sophisticated filled and capped structures, understanding these seven via types enables designers to select appropriate protection for each application while balancing cost, manufacturability, and reliability requirements.
Key takeaways for via protection selection:
Start with the application – Via-in-pad requires Type VII; buried vias often work best with Type V
Consider the pitch – BGAs below 0.65mm typically need via-in-pad technology
Balance cost and reliability – Use Type VII where needed, simpler protection elsewhere
Specify clearly – Include IPC-4761 type designations and acceptance criteria on fabrication drawings
Work with your fabricator – Via fill processes vary; early discussion prevents surprises
As component pitches continue shrinking and HDI technology becomes more prevalent, proper via protection becomes increasingly critical. IPC-4761 gives designers and fabricators a common language for specifying and implementing these essential structures.
Inquire: Call 0086-755-23203480, or reach out via the form below/your sales contact to discuss our design, manufacturing, and assembly capabilities.
Quote: Email your PCB files to Sales@pcbsync.com (Preferred for large files) or submit online. We will contact you promptly. Please ensure your email is correct.
Notes: For PCB fabrication, we require PCB design file in Gerber RS-274X format (most preferred), *.PCB/DDB (Protel, inform your program version) format or *.BRD (Eagle) format. For PCB assembly, we require PCB design file in above mentioned format, drilling file and BOM. Click to download BOM template To avoid file missing, please include all files into one folder and compress it into .zip or .rar format.